Meta-analysis

Benefit and risk: drug-coated balloon angioplasty

Scientists of Jena University Hospital, Germany, conducted a meta-analysis to evaluate benefit and risk of paclitaxel-coated balloon angioplasty compared to conventional balloon angioplasty as therapy of intermittent claudication.

The study confirms an increased all-cause mortality, which has formerly been stated, and found a broad heterogeneity in the effectivity of the procedure depending on pre-dilation strategy, lesion complexity, and the paclitaxel density. The authors raise doubts about a class effect of drug-coated balloons and suggest a highly individualized therapeutic decision. This meta-analysis has recently been published by The Lancet in EClinicalMedicine.

For intermittent claudication, drug-coated balloon angioplasty is the therapy of choice to reduce the risk of target lesion restenosis, and consequently, the necessity of reintervention. However, numerous types of those balloons are distinguished by drug density and coating. Clinical efficacy is not proven for all these types. Moreover, conflicting evidence exists about the risk of mortality that arose from the meta-analysis of Katsanos et al. one year ago.

Photo
In a meta-analysis recently published in EClinicalMedicine, radiologist Ulf Teichgräber from Jena University Hospital draws a heterogeneous picture of drug-coated balloon angioplasty.

Image source: Michael Szabó/Jena University Hospital

The authors working in the department of radiology and the centre for clinical studies took a closer look on 14 randomised trials comparing both procedures for the treatment of femoropopliteal artery disease. Including a total of 2504 patients, the trials were conducted between 2005 and 2019. Actually, the risk of all-cause mortality at two years was indeed increased significantly with a trend to a paclitaxel dose-response relationship, but without evidence of causation. Drug-coated balloon angioplasty significantly increased the risk of target lesion restenosis.

However, results showed substantial heterogeneity due to substantial inter study design differences, inter study lesion complexity differences and inter study device differences. There is a risk of overestimation of the benefit due to high risk of bias within studies, mainly driven by missing blinding of study personal. Head-to-head comparisons of different coated balloons under the same conditions will be needed to evaluate different product efficacy. Additional pharmacological studies are needed to generate robust and meaningful evidence on safety or risk of intra-vessel paclitaxel application. Professor Ulf Teichgräber, the corresponding author of this meta-analysis, states: “There are first trials that are already beginning to examine if sirolimus-coated balloons could be an alternative to paclitaxel-coated ones. Also newer coating technologies of paclitaxel-balloons seem to have less drug loss during the procedure and better drug release to the target lesion. Innovation in this field clearly is leading towards better efficacy and safety.”


Source: Jena University Hospital

22.10.2019

Read all latest stories

Related articles

Photo

Research

First use of vasoprotective antibody in cardiogenic shock

Scientists at the German Centre for Cardiovascular Research (DZHK) have started a study to find out whether a monoclonal antibody restoring vascular integrity is safe and has positive effects on…

Photo

Tailored treatment needed

Half of patients on statins fail to reach ‘healthy’ cholesterol level after 2 years

Half of patients prescribed statins in primary care fail to reach ‘healthy’ cholesterol levels after two years of treatment with these drugs, reveals research published online in the journal…

Photo

Oral contraceptives

Can birth control pills keep you from recognising emotions?

The pill could be blurring your social judgement ‒ but perhaps not enough so you'd notice. By challenging women to identify complex emotional expressions like pride or contempt, rather than basic…

Related products

Eppendorf – Mastercycler nexus X2

Research Use Only (RUO)

Eppendorf – Mastercycler nexus X2

Eppendorf AG
Quart – DSA Test Phantom

Testing Devices

Quart – DSA Test Phantom

QUART GmbH
Sarstedt – Low DNA Binding Micro Tubes

Research Use Only (RUO)

Sarstedt – Low DNA Binding Micro Tubes

SARSTEDT AG & CO. KG
Shimadzu – CLAM-2030

Research Use Only (RUO)

Shimadzu – CLAM-2030

Shimadzu Europa GmbH