Researchers conducting contactless ECG monitoring experiments
Researchers conducting contactless ECG monitoring experiments

Image source: USTC/Prof. Chen's team

News • Mechanical heart activity captured

Contactless ECG monitoring technique developed

Recently, a team led by Prof. Yan Chen and researcher Qibin Sun from the University of Science and Technology of China (USTC) achieved contactless electrocardiogram (ECG) monitoring through a millimeter-wave radar system.

Their work was published in IEEE Transactions on Mobile Computing

Chronic and cardiovascular diseases (CVDs) claim the lives of about 18.6 million people each year. Continuous ECG monitoring has been proven to be crucial to diagnosing CVDs, and thus is widely utilized in the early diagnosis and subsequent treatment of CVDs. However, current ECG monitoring requires the body attached electrodes which leads to an uncomfortable user experience. Therefore, it is challenging to implement long-term continuous ECG monitoring in daily life, which leads to the loss of transient abnormal ECG states and delays in the diagnosis of CVDs. 

To solve this problem, the team developed millimeter-wave radar to measure the cardiac mechanical activity rather than electrical activity. They first scanned the heart using the millimeter-wave radar, and then filtered the reflections to extract 4D cardiac motion signals using a series of signal processing algorithms. Finally, a data-driven deep neural network was applied to model the nonlinear relations between cardiac mechanical conduction and electrical conduction and solve the domain transformation problem, consequently reconstructing the ECG.

Working principle of contactless ECG monitoring
Working principle of contactless ECG monitoring

Image source: USTC / Chen J et al., IEEE Transactions on Mobile Computing 2022

In this study, the team conducted 200 experimental trials on 35 participants during four different physiological states to simulate daily conditions. The radar was placed within 0.5 meters above the torso chest, preventing any skin irritation or any other discomfort from direct skin attachment. The team achieved a median timing error of less than 14 milliseconds and a median morphology accuracy higher than that of over 90% of the conventional ECG. This new method also achieved a 90-percentile error of 9 ms for R-R interval timing, which is the golden standard for diagnosing heart arrhythmia, further verifying its medical value. 

The work provides a novel method for ECG monitoring, demonstrates immense potential for CVDs diagnosis and could inspire future medical applications based on non-intrusive and more reliable systems. 


Source: University of Science and Technology of China

14.12.2022

Related articles

Photo

Article • Wearables at Medica 2022

Smart ring medical device for 24/7 blood pressure monitoring

A smart-ring medical device is emerging as an effective and discreet wearable for round-the-clock blood pressure monitoring. Using photoplethysmography (PPG) signals to measure the bloodstream 24/7…

Photo

News • Merging modalities

AI combines ECG and X-ray to diagnose arrhythmic disorders

Kobe University Hospital’s Dr. Makoto Nishimori and Project Assistant Professor Kunihiko Kiuchi et al. (of the Division of Cardiovascular Medicine, Department of Internal Medicine) have developed…

Photo

Article • Focus on TAVI

Transcatheder aortic valve implants

With transcatheder aortic valve implants (TAVI) forming some 20% of all heart valve replacement procedures today, and the technology constantly developing, the 'real art' to the intervention's…

Related products

Subscribe to Newsletter