TestingDevices RadBook 2014 179 Highlights •• The QUART dent/digitest 2D dental imaging test phantom is designed to test parameters according to DIN and IEC QA/QC requirements. •• It features patient equivalent filtration and objects to perform full-scale image quality analyses. •• Parameters - Spatial resolution - High-contrast resolution - Low-contrast resolution - Homogeneity/artefacts - Radiation field/tube alignment •• The phantom is also available with enhanced resolution and low-con- trast objects (M1 and M2 version) for a critical examination of image quality related parameters. dent/digitest Dental QA/QC Test PhantomQuart Highlights •• For quality checks at digital / conventional radiographic and fluoroscopic X-ray units (according to DIN 6868-4, 2007) •• Test parameters: - Spatial resolution - Verification of used kV-range - Contrast resolution - Alignment of light and X-ray field - Geometry symmetry - Image scale, Dimensions in mm: 300 x 300 x 18.5 Test Device Primus LIBA Dosimetry Highlights Consisting of: •• 40 mm base plate with integrated Al step wedge with 14 steps from 0 to 5.2 mm and 2 rows of steel balls for checking the image limitations towards the thorax side •• 6 mm structural plate with recess for test inserts, 2 rows of steel balls with integrated turnable resolution test in line groups of 5, 6, 7, 8 and 10 Lp/mm •• PMMA-test insert with square marking •• Test insert for constancy tests - ACR •• Test insert high contrast resolution •• Test insert contrast to noise ratio •• Carrying case •• Attenuation body 2 x 20 / 2 x 10 mm Test device PASMAM 1054 CIBA Dosimetry Highlights Consisting of: •• 40 mm basic body with integrated Al step wedge with 14 steps from 0 to 5.2 mm •• 6 mm structural plate with recess for test inserts, 2 rows of steel balls with integrated turnable resolution test in line groups of 5, 6, 7, 8 and 10 Lp/mm •• Attenuation body 3 x 20 / 1 x 10 / 1 x 6 mm PMMA (at some X-ray units necessary) •• Test insert for acceptance tests with golden discs - AP •• Test insert PMMA with square marking •• Test insert for constancy tests - ACR •• Test insert high contrast resolution •• Test insert contrast to noise ratio •• Carrying case Test device PASMAM 1054 A/CIBA Dosimetry Highlights •• For acceptance and constancy tests (DIN V 6868-152, DIN EN 61223-3-2 and DIN 6868-7 / EPQC (EUREF) in conventional mammography •• Test Parameters: - Object thickness and tube voltage compensation resp. AEC reproducibility - Attenuation factor - Spacial resolution - Contrast and image resolution - Artifacts - Geometry - Check of missed tissue at chest wall Test Device Mammo-152IBA Dosimetry Highlights •• For quality checks in conventional radiography and fluoroscopy (DIN 6868-3, -4 and IEC 61223-2-9 / -2-11) •• Test Parameters: - Spatial resolution - Alignment of light and X-ray field - Geometry symmetry - Contrast resolution - Measuring areas for optional density Test Device ETR1 incl. Centering TubeIBA Dosimetry