Please activate JavaScript!
Please install Adobe Flash Player, click here for download

Radbook 2014

MolecularImaging RadBook 2014 136 Highlights •• Only PET•CT where planning and scanning is based on a single continuous table motion •• Finest detail in every organ with industry’s highest vol. resolution of 87 mm³** •• Can lead to 25% less scan time per patient with single scan protocol using motion manage- ment •• Whole-body PET scan in only 5 minutes •• Accurate and reproducible quanti- fication in all dimensions enables a more confident interpretation •• Zero overscan and lowest dose reduces radiation risk enabling more utilization of PET•CT for treat- ment monitoring •• Improved patient comfort with 78 cm bore and patient’s continuous sense of scan progress * Biograph mCT Flow is not commercially available in all countries. Due to regulatory reasons, its future availability cannot be guaranteed. Please contact your local Siemens organization for further details. ** Based on competitive literature available at time of publication. Compared to PMT- based devices. Data on file. 87 mm³Volumetric Resolution up to 221 mm (axial)Field of View 78 cmGantry Opening Biograph mCT Flow*Siemens Highlights •• Molecular CT – quantification redefined •• Increased confidence in quantitative results with automatic daily quality control with normalization •• Superb visualization, particularly of small tumors with industry-leading volumetric resolution* of 87 mm³ •• Whole-body PET scans in only 5 minutes •• Lowest possible dose and high-speed workflow enabled by FAST CARE technologies •• Increase revenue with a 78 cm bore and state-of-the-art CT combining precise anatomic and metabolic imaging for radiation therapy * Based on competitive literature available at time of publication. Compared to PMT-based devices. Data on file. up to 221 mm (axial) 78 cm 87 mm3 Field of View Gantry Opening Volumetric Resolution Biograph mCTSiemens Highlights •• Affordable performance •• Industry-leading PET resolution* of 87 mm³ for lesion visualization, including small tumors •• Accurate SUV quantifi cation and full HD lesion detection with motion-frozen images •• One-click gating integrated in daily routine •• Image virtually all patients** with unique 78 cm wide bore and short tunnel •• Increase referral base with molecular resolution for bariatric and radiation therapy patients •• 24/7 proactive monitoring ensures maximum uptime * Based on competitive literature available at time of publication. Compared to PMT-based devices. Data on file. ** Patients up to 227 kg /500 lb up to 164 mm (axial) 78 cm 87 mm3 Field of View Gantry Opening Volumetric Resolution Biograph mCT 20 ExcelSiemens 7 Highlights Leading edge technology for advanced applications and demanding academic practices •• Designed for short-lived tracers – high count rate capability •• Treatment assessment and quantitative consistency with Q.Suite •• VUE Point HD – 3D iterative reconstruction with Time of fl ight capability •• Optimized for complex research protocols •• CT fl exibility •• LBS detector design 2 mm (w.SharpIR) 7.5 cps/kBq 70 cmFOV Sensitivity Resolution Discovery PET/CT 710GE Healthcare Highlights PET/CT solution with all-around performances in oncology, cardiology & neurology •• Low dose1 and fast scans, high sensitivity, optimized for F18 •• Treatment assessment and quantitative consistency with Q.Suite •• Advanced treatment planning & Motion management •• Q.Core for dedicated PET reconstruction •• Clinical research capability •• CT fl exibility •• BGO detector design 1 The ASiR reconstruction algorithm may allow for reduced mA in the acquisition of diagnostic images, thereby reducing the dose required. In clinical practice, the use of ASiR may reduce CT patient dose depending on the clinical task, patient size, anatomical location and clinical practice. A consultation with a radiologist and a physicist should be made to determine the appropriate dose to obtain diagnostic image quality for the particular clinical task. Sensitivity 10 cps/kBq 2 mm (w.SharpIR) 70 cmFOV Resolution Discovery PET/CT 610GE Healthcare pet-CT 3 RADBOOK2014 Please visit us at www.radbook.eu

Pages Overview