Toshiba · Aquilion LB Rotation speed Coverage per rotation Slices per rotation Slice thickness 0.5 s 3.2 cm 32 0.5 mm COMPUTED TOMOGRAPHY ◼ CONEBEAM CT Cela · NewTom 5G XL FOV Voxel size Emission Time 21 x 19 cm up to 6 x 6 cm 100 μm HiRes max 5.4 s (ECO 0.9 s) Highlights • PUREViSION detector • 90 cm bore • 70 cm FOV • 85 cm extended FOV • 2 mm @ 3 HU LCR • 300 kg patient load table • AIDR 3D iterative reconstruction • SEMAR (Metal Artifact Reduction) • Respiratory gating (option) • Oncology table top (option) • CT DSA with SURESubtraction (option) • SUREFluoro (option) • Reduced energy consumption Highlights • Cone Beam CT with open gantry and supine position. Backside access available. • High definition volumetric images of bone tissues, non-overlapping sections and fewer artifacts • Safe Beam: Automatic detection minimal necessary Dose, Pulsed emission • Extensive range of disciplines in Orthopaedics, Otorhinolaringology, Oral and Maxillofacial surgery • “Cine X” Dinamic acquisition, “Ray 2D” single 2D acquisition Cela · NewTom VGi evo FOV Voxel size Emission Time 24 x 19 cm up to 5 x 5 cm 100 μm HiRes max 4.3 s (ECO 0.9 s) Planmed Oy · Planmed Verity Scan volume Spacial resolution Scan time 16 cm diameter x 13 cm, 16 cm diameter x 7 cm 0.4 mm, 0.2 mm 18 s Highlights • Cone Beam CT seated/standing patient positioning • High definition volumetric images of bone tissues, non-overlapping sections and fewer artifacts • Safe Beam: Automatic detection minimal necessary Dose, Pulsed emission • Extensive range of disciplines in Otorhinolaringology, Oral and Maxillofacial surgery • ”Cine X” Dinamic acquisition, “Sharp 2D” from CBCT acquisition VILLA SISTEMI MEDICALI · Rotograph Evo 3D Scan volume Voxel size Scan time Max. 93 x 82 mm (full dentition) 185 μm 11.2 s (exposure) Highlights • 3-in-1 dental system with “Cone Beam” technology: Pan, Ceph, 3D • Pan-3D detector always ready to operate: no need to switch it from Pan to 3D mode • Optional Evo Xp Examination Module enlarges the traditional Panoramic views • Accessible to any patient, including ones on wheelchairs • Selection of reduced FOVs, focused on maxillary dentition and manibular dentition, for dose reduction Highlights • Cone Beam CT (CBCT) scanner dedicated to extremity and maxillo facial imaging • Weight-bearing imaging • kV range 80 - 96 • High quality 3D-imaging with low dose • Advanced artefact removal algorithms • Compact, mobile, easy to site • Motorized, soft-surface gantry adapts to the patient RADBOOK 2017 Please visit us at www.healthcare-in-europe.com RADBOOK 2017 17