MOLECULAR IMAGING ◼ Siemens Healthineers · Symbia Evo Excel* Siemens Healthineers · Symbia Evo* System sensitivity Intrinsic spatial resolution Field of View 202 cpm / μCi (LEHR 3 / 8" at 10 cm) ≤ 3.8 mm FWHM in CFOV 533 x 387 mm System sensitivity Intrinsic spatial resolution Field of View 202 cpm/μCi (LEHR 3 / 8" at 10 cm) ≤ 3.8 mm FWHM in CFOV 533 x 387 mm Highlights • Smallest** room size in its class, reducing costs associated with room remodeling and expansion • Ability to image every patient*** and improve patient comfort with a larger bore; a high-capacity, low-height patient bed; and hospital bed imaging capabilities • Industry-leading** image quality delivers accurate and reproducible clinical information to support physicians’ diagnostic confidence * Symbia Evo Excel is not commercially available in all countries. Due to regulatory reasons, their future avail- ability cannot be guaranteed. Please contact your local Siemens Healthineers organization for further details. ** Based on competitive literature available at time of publication. Data on file. *** Patients up to 227 kg. Highlights • Save up to 50 %** more time and potentially double patient throughput with automated quality control and collimator exchange, as well as ultra-fast cardiac imaging • Image every patient*** and improve patient comfort with a larger bore; a high-capacity, low-height patient bed; and hospital bed imaging capabilities • Industry-leading** image quality delivers accurate and reproducible clinical information to support physicians’ diagnostic confidence * Symbia Evo is not commercially available in all countries. Due to regulatory reasons, its future availability cannot be guaranteed. Please contact your local Siemens Healthineers organization for further details. ** Based on competitive literature available at time of publication. Data on file. *** Patients up to 227 kg. Siemens Healthineers · Symbia S GE Healthcare · Discovery NM / CT 670 ES System sensitivity Intrinsic spatial resolution Field of View 202 cpm / μCi (LEHR 3 / 8" at 10 cm) ≤ 3.8 mm FWHM in CFOV 533 x 387 mm System sensitivity Energy resolution (NEMA) Field of View 270 cpm / μCi 9.8 % 540 x 400 mm SPECT-CT Highlights • Siemens Healthineers AUTOFORM, a unique collimator design that allows for up to 26 %* higher sensitivity • IQ•SPECT ultra-fast cardiac solution provides a complete cardiac work-up in only 5 minutes • Automated Quality Control saves time and reduces radiation exposure • Automated Collimator Changer increases workflow efficiency * Based on competitive literature available at time of publication. Data on file. Highlights All great capabilities of Discovery NM 680 plus: • Full diagnostic Optima 540 8 slice CT for localization and diagnostic CT studies • Designed to enable 16 min Whole body + Hybrid SPECT / CT scan • CT Dose management with ASiR • IQE3 enables more coverage w/ fewer artifacts • CT Calcium Scoring and Angio functionality • Expanded NM dose management Evolution Toolkit • SUV Quantification for every radionuclide GE Healthcare · Optima NM / CT 640 System sensitivity Energy resolution (NEMA) Field of View 270 cpm / μCi 9.8 % 540 x 400 mm Philips · BrightView XCT Resolution Sensitivity Field of View 3.3 mm, FWHM intrinsic 2.77 cpm / μm Ci (LEGP) 40.6 x 54 cm Highlights All great capabilities of Discovery NM 630 plus: • SPECT / CT low-dose imaging without compromise • Low total cost of ownership, with a technology continuum for upgradability • Acquisition speed that drives efficiency • Designed to enable 16 min Whole body & Hybrid SPECT / CT scan • Simplified hybrid scan setup Highlights • Flat panel CT allows acquisition of the entire heart volume in just one rotation to aid in cardiac studies • Concurrent imaging allows for shorter exams and smarter assessments. • Full Iterative Technology (FIT) now available on the BrightView XCT uses advanced algorithms for the truest picture possible RADBOOK 2017 131