DUAL SOURCE CT · · SOMATOM Force Siemens Up to 80 cm Gantry bore Up to 737 mm / sec Scan speed Up to 2,600 mA (2 x 1,300 mA) Power 384 (2 x 192) Slices per rotation Highlights • Kidney-friendly scanning with significantly reduced contrast media amounts required (low kV imaging) • Low dose early detection with up to 50 % dose reduction •“Free-breathing”CT with outstanding native temporal resolution • Fastest scan mode with the Turbo Flash spiral and a temporal resolution of 66 ms • Precise dose neutral Energy quantification to add tissue information to morphology · · SOMATOM Definition Flash Siemens Yes, DS Dual Energy 75 ms (Full Body) Temporal resolution 200 kW (2 x 100 kW) Power Up to 458 mm/sec Scan speed Highlights • FAST CARE technology for workflow optimization (like FAST DE Results, FAST 3D align etc) • Stellar detector for optimized low dose imaging and in- creased spatial resolution • Split-second thorax imaging: avoiding breath hold or sedation in pediatric patients • Simple low dose – all heart-scanning, without heart rate control, stability or patient size limitations VOLUME CTS · · Revolution CT GE Healthcare 103 kW Power 0.23 mm Spacial resolution 512 Slices per rotation Highlights • Gemstone Clarity Detector for 80 or 160 mm detector coverage • Unique image chain hardware with Volume HD reconstruction • ASiR-V – up to 82 % lower dose* • Best effective temporal resolution enabled by 0.28-second rotation speed combined with intelligent mo- tion correction for excellent cardiac imaging at any heart rate • Aorta, heart and lung in just 1 sec * Compared to prior generation · · Revolution HD GE Healthcare 100 kW Power 0.23 mm Spacial resolution 128 to 256 Slices per rotation Highlights Revolution HD can reach any part of the body of virtually any patient and perform both generalized and specia lized clinical applications, including: • Gemstone Spectral Imaging – quantitative dual-energy CT • Cardiac GSI • Neuro imaging – Revolution HD ensures ample coverage to perform perfusion studies of the entire brain • Gemstone detector – highest spatial resolution (0.23 mm)* • SmartMAR – rawdatabased metal artifact reduction * Compared to prior generation Highlights • X-ray tunbe: 7.5 MHU • Minimum scan time for all types of examination: 0.35 seconds • Minimum slice thickness: 0.625 mm • Open design concept with aperture diameter of 750 mm • Unique laterally moving patient table • New algorithms for iterative reconstruction: Intelli IP Advanced • 475 mm wide patient table with weight limit of 230 kg · · SCENARIA Hitachi 72 kW Power 17.1 Lp / cm Spacial resolution 64 / 128 Slices per rotation RADBOOK 2016 9 COMPUTED TOMOGRAPHY ◼ RADBOOK 20169