RADBOOK 2015 9 COMPUTED TOMOGRAPHY ◼ VOLUME CTS Highlights • 64 and 128 slices imaging • Latest innovations in a 40 mm detector CT • Leadership in advanced cardiac CT • Intelligent cardiac CT with Snapshot • Assist and Snapshot Freeze • Unique workflow features • Real time recon (55 fps) • Fast acquisitions with high helical pitch (1.531) • Automatic reconstruction with 10 PMR • Up to 500 slices coverage for perfusion • 60% lower CO2 emission and energy saving • Scalable and modular • Compact for easy siting (18 sqm) • Integrated ASiR reconstruction · Optima CT660 FREEdomGE Healthcare 0.35 s (cardiac 0.058 s equivalent withSnapshot Freeze)Rotation 128Channels Highlights • 64 and 128 slices imaging • Latest innovations in a 40 mm detector CT • Leadership in advanced cardiac CT • Intelligent cardiac CT with Snapshot • Assist and Snapshot Freeze • Unique workflow features • Real time recon (55 fps) • Fast acquisitions with high helical pitch (1.531) • Automatic reconstruction with 10 PMR • Up to 500 slices coverage for perfusion • 60% lower CO2 emission and energy saving • Scalable and modular • Compact for easy siting (18 sqm) • Integrated ASiR reconstruction · Optima CT660 Spatial EnhancedGE Healthcare 0.4 s (cardiac 0.35 s)Rotation 128Channels 40 mm isotropic, 128i – 0.625 mm (overlap), 64i – 0.625 mm (overlap), 32i – 1.25 mm, 16i – 2.5 mm, 8i – 5 mm, 4i – 10 mm Coverage Yes, dose neutral (Dual Source)Dual Energy 75 ms (0.28 s with Dual Source)Acquired temp. res. Highlights • FAST CARE technology for work- flow optimization (like FAST DE Results, FAST 3D align etc) • Stellar detector for optimized low dose imaging and in- creased spatial resolution • Split-second thorax imaging: avoiding breath hold or seda- tion in pediatric patients • Sub-mSv heart scanning to cover the entire heart in only 250 ms • ADMIRE – Siemens’Advanced Modeled Iterative Reconstruction – smoothly integrates iterative reconstruction • Dose neutral Dual Energy for a second contrast in daily routine · SOMATOM Definition FlashSiemens 200 kW (2 x 100 kW)Generator power 256 (2x128)Acquired slices/rot DUAL SOURCE Highlights • Kidney-friendly scanning with significantly reduced contrast media amounts required • Low dose early detection with up to 50% dose reduction •“Free-breathing”CT imaging with outstanding native temporal resolution • The fastest, most verstatile scan mode with the Turbo Flash spiral • 4D imaging at half the dose • Precise Dual Energy quantification to add tissue information to morphology · SOMATOM ForceSiemens Up to 80 cm4D scan range Up to 737 mm/secScan speed Up to 2,600 mA (2x1,300 mA)Power reserves 384 (2x192)Acquired slices/rot Highlights The Discovery CT750 HD can reach any part of the body of virtually any patient and perform both generalized and specialized clinical applications, including: • Gemstone Spectral Imaging – the first quantitative dual-energy CT on the market • Cardiac imaging – highest spatial resolution in the industry at 18.2 lp/cm • Neuro imaging – the Discovery CT750 HD ensures ample coverage to perform perfusion studies of the entire brain · Discovery CT750 HDGE Healthcare 18.2 lp/cmSpacial resolution 64Channels Highlights • X-ray tunbe: 7.5 MHU • Minimum scan time for all types of examination: 0.35 seconds • Minimum slice thickness: 0.625 mm • Open design concept with aperture diameter of 750 mm • Unique laterally moving patient table • New algorithms for iterative reconstruction: Intelli IP Advanced • 475 mm wide patient table with weight limit of 230 kg · SCENARIAHitachi 72 kWPower 17.1 Lp/cmSpacial resolution 64/128Slices per rotation RADBOOK 20159