RADBOOK 2015 43 INJECTORS ◼ Highlights • Fast high-pressure injections for angiography and multiphase injection profiles for computed tomography • Wireless injector unit with rechargeable batteries • Wireless touchscreen remote control (as an option) • Wall or ceiling suspension system • Integrated heated syringe holder for Easy Loading Syringe (ESL) 200 ml • 120 injection profiles can be defined and stored by the user (60 angio / 60 CT) • Aluminium housing – Interface (as an option) ·· Accutron HPMEDTRON Automatic or manual filling, filling speed 1-4 ml / s opt. high-pressure tube systems with check valves Filling of syringes Angio mode: 83 bar (1,200 psi), CT mode: 21 bar (305 psi), programmable in 1 bar increments Max. injection pressure 200 mlCapacity Angio mode: 0.1 – 30 ml / s, CT mode: 0.1 – 10 ml / s programmable in 0,1 ml / s increments Flow rate Highlights • Wireless injector unit with rechargeable batteries • Touchscreen control panel with different languages • Wireless touchscreen remote control • Up to 6 phases – secured injection position • Use of prefilled syringes (as an option) • Alternatively, input of flow rate or phase duration • Pressure graph • Aluminium housing ·· Accutron MRMEDTRON Automatic or manual filling, filling speed 1 – 5 ml / s optimized tube systems with check valve Filling of syringes 21 bar (304 psi)Max. injection pressure 64 ml or 200 ml (CM), 65 ml or 200 ml (NaCl) Easy Loading Syringe (ELS) Capacity 0.1 – 10 ml / s programmable in 0.1 ml / s increments Flow rate Highlights • Unique roll pump system for more cost- effectiveness • Two-piece tubing system with check valves and particle filter • 24 hours on-label-use of the pump tubing for highest hygiene • Direct and multiple injections from all commercially available media containers • 5 detectors to reliably prevent air injection and selectable range of pressure limits • Efficient workflow and fast patient changeover ·· INJECT CT motion (XD 8000)ulrich 17 bar (246.6 psi)Max. injection pressure All commercially available media containers (CM 2 x 500 ml, NaCl 1 x 1,000 ml) Capacity CTApplication Highlights • Wireless injector unit with rechargeable batteries • Integrated heated syringe holder for Easy Loading Syringe (ELS) • Wireless touchscreen remote control • Use of prefilled syringes (as an option) • Secured injection position (built-in sensor) • Alternatively, display of injection parameters or pressure graph • Aluminium housing – wall or ceiling suspension • CANopen Interface (as an option) ·· Accutron CT-DMEDTRON Automatic or manual filling, filling speed 1 - 5 ml / s optimized tube systems with check valve Filling of syringe 21 bar (304 psi)Max. injection pressure 200 ml (CM), 200 ml (NaCl)Easy Loading Syringe (ELS)Capacity For both injection units: 0.1 – 10 ml / s, programmable in steps of 0.1 ml / s Flow rate Highlights • Wireless injector unit with rechargeable batteries • Multiphase program controlled injection of CM & NaCl • Single or multi injection mode • Integrated heated syringe holder for Easy Loading Syringe (ELS) • Touchscreen control panel with different languages • Up to 3 phases – pressure graph – secured injection position (built-in sensor) • 60 injection profiles can be defined and stored by the user • Interface (as an option) – Aluminium housing ·· Accutron HP-DMEDTRON Automatic or manual filling, filling speed 1-4 ml / s opt. high-pressure tube systems with check valves Filling of syringes Angio mode: 83 bar (1,200 psi), CT mode: 21 bar (305 psi), programmable in 1 bar increments Max. injection pressure 200 ml (CM), 200 ml (NaCl) Easy Loading Syringe (ELS)Capacity Angio mode: 0.1 – 30 ml / s, CT-mode: 0,1 – 10 ml / s programmable in 0,1 ml / s increments Flow rate Automatic or manual filling, filling speed 1 – 4 ml / s optimized tube systems with check valve Filling of syringes 21 barMax. injection pressure Highlights • Contrast medium injector with integrated infusion pump • Wireless injector unit with rechargeable batteries • Touchscreen control panel with different languages • Wireless touchscreen remote control • Up to 6 phases • Alternatively, input of flow rate or phase duration • Aluminium housing ·· Accutron MR3MEDTRON CM: 64 ml (ELS), NaCl: 200 ml (ELS) Infusion pump: 50 ml Capacity CM / NaCl: 0,1 – 10 ml / s, programmable in 0,1 ml / s increments, Infusion pump: 0,001 – 30 ml / min Flow rate RADBOOK 201543