Please activate JavaScript!
Please install Adobe Flash Player, click here for download

EH5

Administration of fluids even during the MR-examination! Only one remote control required! Tried-and-tested innovative Accutron® technology Made in Germany! The new Accutron® MR3 Hauptstrasse 255 · D-66128 Saarbruecken For more info: www.medtron.com Contrast medium injectors and consumables for CT, MRI and angiography New: with integrated infusion pump! EUORPEAN_HOSPITAL_1-4_Seite_MR3_Anzeige 09.10.14 10:01 Seite 1 EUROPEAN HOSPITAL  Vol 23 Issue 5/14 RADIOLOGY Creating the Holy Grail of medical imaging Report: Sascha Keutel Among new medical imaging innova- tions exhibited at Medica 2014 is a phase-contrast X-ray technique to bring greater precision to breast cancer assessment and improve biopsy diagnostics. We asked research pioneer Professor Marco Stampanoni, a key figure in the development of this technique, to explain how it works. ‘Phase-contrast X-ray imaging can be considered one of the holy grails of medical imaging,’ he pointed out. ‘Since the first discovery of X-rays in 1896 by Röngten, scientists have worked very hard to address a fundamental issue: how to increase contrast in soft-tissue while keep- ing the dose deposition under con- trol? Namely, in conventional X-ray imaging (radiography or CT) as it is performed daily in hospitals, the contrast is essentially determined by the absorption of X-rays in the body – which, as the name sug- gests, is directly related to the dose deposition. ‘On the other hand, to gener- ate contrast, phase-contrast imaging, exploits refraction and scattering signals from the body. It can be shown that while the absorption signal might be small for a soft- tissue specimen such as the breast, the phase contrast signal can be much larger. Being able to detect such a signal and convert it into an interpretable image might provide a formidable new radiological tool: high soft-tissue sensitivity (so far a prerogative of MRI) at excellent spatial resolutions within a short time, which are typical features of CT scanners.’ Back to the beginning ‘The development of phase sensitive X-ray techniques goes back to the mid-sixties, first with interferometric experiment using crystals. Further, with the advent of synchrotron facil- ities, X-ray imaging experienced a first revolution, as coherent X-rays were finally in reach. Coherence is the intrinsic property one needs in order to observe interference phe- nomena which, in the end, allows access to the phase information. In the last decade we saw the development of many approaches: propagation-based imaging, diffrac- tion enhanced imaging, coherent diffraction imaging, gratings inter- ferometry and ptychography, to cite a few. ‘These methods perform phase- contrast imaging at different length scales, from a single cell up to whole organ imaging.’ Further objectives for phase-contrast X-ray ‘Out of the many techniques devel- oped so far, gratings interferometry seems to be the most promising, with respect to potential clinical applications. This approach, pio- neered at the Paul Scherrer Institute in Switzerland, has been proven to work very efficiently on conven- tional X-ray sources, i.e. without the need of a large-scale facility like a synchrotron. This raised the interest of the medical community, which, as mentioned, is eager to improve soft- tissue differentiation at high-reso- lution keeping dose under control. ‘Our research aims to develop the technology (hardware/software) to finally bring phase-contrast imaging into hospitals, to improve diagnostic capabilities to benefit the entire population. An ideal entry point for this technology is mammography, a popular radiologic technique to investigate breast tissue. It is well known, also in relation with many active screening programs, that dose delivery is critical issue. It would be of paramount relevance if a technol- ogy were to be available that could significantly improve sensitivity to soft-tissue, sharpness as well as lesions delineation and microcalcifi- cations visibility. ‘The identification of microcal- cifications is one goal of breast cancer screening and early detec- tion of pre-malignant and malignant lesions. Breast calcifications are common on mammograms, being especially prevalent after meno- pause. Although they are usually benign, certain morphologic (e.g. fine pleomorphic or fine linear) and distribution (e.g. clustered or seg- mental distribution) descriptors may indicate breast cancer.’ Other possible applications ‘Currently, it looks like mammog- raphy is very well suited for a first clinical application of phase contrast imaging. Whether this technology will make it into more complex systems, for instance a human-body CT, still needs to be verified and many teams worldwide are working toward this aim. Further, it has to be pointed out that phase contrast imaging promises to be very useful for applications outside the medical field, for example in non-destructive testing or homeland security.’ Radiation exposure comparisons ‘This is obviously a critical issue, which cannot be answered yet with a comprehensive quantitative state- ment, because there are no clinically compatible phase-contrast systems available that have been pushed to perform at their physical limits, as is the case, for instance, for con- ventional, absorption-based instru- ments. The theory is very promising and the hope is that one day a phase contrast mammography sys- tem, with dose constraints within the actual regulation limits and sig- nificantly improved image quality, can be deployed to a hospital.’ Advantages and disadvan- tages over others The most fascinating aspect of phase contrast imaging is that it should be possible to achieve a signifi- cantly improved soft-tissue differ- entiation compared to conventional X-ray based systems. Being an X-ray technique, it is also supposed to be significantly cheaper and eventually provide a better spatial resolution than conventional MRI. ‘However, phase contrast is based on ionising radiation, and there- fore the minimisation of the dose delivered to a patient as well as the delicate balance between such dose and the desired and/or required diagnostic information have always to be taken into account.’ Research results ‘With clinical partners we have con- tributed to the early period of phase contrast imaging in a clinical envi- ronment. For the first time, we presented images of the human breast investigated by this novel technology (outside a synchrotron) and we statistically evaluated the potential impact of such a technol- ogy in a diagnostic context. From our studies it appeared clear that sharpness, contrast, lesion delinea- tion and microcalcifications detec- tion are improved. ‘We recently indicated that it might even be possible to discrimi- nate between two types of microcal- cifications. If statistically confirmed, this could eventually provide an additional descriptor for a scoring system to improve risk stratification.’ Entering clinical routine ‘Introducing a new technology into clinical routine is notably a long and complicated task. We are confident that our approach will convince the medical community that phase con- trast can effectively improve their diagnostic capabilities. If this can be shown on a sufficient large scale and for a wide range of applications, then it should be possible to design, build and certify an instrument, which will make it. ‘As technology developers we must show that this technique can be brought so far that it can be effi- ciently transferred to a hospital. ‘Then, the radiologists need to assess the capability of this tech- nique and confirm that it indeed provides a significant benefit to their diagnostic process. These are the two fundamental pre-requisites for a successful story.’ A physics graduate (1998) from ETH Zurich, in 2002 Marco Stampanoni also graduated in synchrotron-based tomographic microscopy. In 2013 he became an associate professor there, focusing on X-ray imaging in the IT and electrical engineering department. Today he is a professor for the Institute of Biomedical Engineering at the University and at ETH Zurich, where he leads the X-ray Imaging and Microscopy Division. At the Paul Scherrer Institute he also heads the Swiss Light Source (SLS) X-ray Tomography group consisting of 19 people – two staff scientists, seven post-docs, eight PhD students, a computer engineer and technician. Dr Stampanoni’s research encompasses phase contrast X-ray imaging and microscopy, real-time tomographic micro-imaging, nanotomography and novel radiological methods for clinical applications and more general non- destructive testing. In 2012 he received an ERC Grant for his phase-contrast X-ray imaging project and he won the Dalle Molle Foundation Award for his pioneering work on X-ray phase-contrast mammography. Phase-contrast X-ray Absorption image - conventional radiography (1895) Differential phase image Scatter image 12 EUORPEAN_HOSPITAL_1-4_Seite_MR3_Anzeige 09.10.1410:01 Seite 1

Pages Overview